True RMS Wireless Clamp Meter with iFlex & CAT III 1500V – Enviro Test Construct

True RMS Wireless clamp meter with iFlex probe, CAT III 1500V rating, thin jaw for tight spaces, DC power measurement, and IP54 protection. 

SKU: ETCCM-105 Category:

Overview

Enviro Test Construct True RMS Wireless Clamp Meter with iFlex & CAT III 1500V is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, and data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9A dc or ac through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind and are also rated to CAT III 1500 V dc. 

 

Features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Sturdy IP54 rated for outdoor use
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • DC power measurement, showing readings in kVA
  • Audio Polarity indicator helps prevent accidental misfires
  • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via Fluke Connect software
  • When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces
  • The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements

 

Technical Specifications

AC Range999.9 A
AC Resolution0.1 A
AC Accuracy2 % + 5 digits (10 to 100 Hz)
2.5 % + 5 digits (100 to 500 Hz)
AC Crest Factor (50/60 Hz)2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2 % for C.F. > 2
AC Current Range999.9 A
2500 A
AC Current Resolution0.1 A (≤ 999.9 A) 1 A (≤ 2500 A)
AC Current Accuracy3 % RD + 5 digits (10 to 500 Hz)
AC Current Crest Factor (50/60 Hz)2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2 % for C.F. > 2
DC Current Range999.9 A
DC Current Resolution0.1 A
DC Current Accuracy2 % RD + 5 digits (when using the ZERO function to compensate for offsets)
AC Voltage Range600 V
1000 V
AC Voltage Resolution0.1 V (≤600 V)
1 V (≤1000 V)
AC Voltage Accuracy1 % RD + 5 digits (20 to 500 Hz)
DC Voltage Range600 V
1500 V
DC Voltage Resolution0.1 V (≤ 600 V)
1 V (≤ 1500 V)
DC Voltage Accuracy1 % RD + 5 digits
mV DC Range500 mV
mV DC Resolution0.1 mV
mV DC Accuracy1 % RD + 5 digits
Jaw Amps Frequency Range5 to 500 Hz
Jaw Amps Frequency Resolution0.1 Hz
Jaw Amps Frequency Accuracy0.5 % RD + 5 digits
Jaw Amps Frequency Trigger Level5 to 10 Hz, ≥ 10 A
10 to 100 Hz, ≥ 5 A
100 to 500 Hz, ≥ 10 A
Flexible Current Probe Amps Frequency Range5 to 500 Hz
Flexible Current Probe Amps Frequency Resolution0.1 Hz
Flexible Current Probe Amps Frequency Accuracy0.5 % RD + 5 digits
Flexible Current Probe Amps Frequency Trigger Level5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Voltage Frequency Range5 to 500 Hz
Voltage Frequency Resolution0.1 Hz
Voltage Frequency Accuracy0.5 % RD + 5 digits
Voltage Frequency Trigger Level5 to 20 Hz, ≥ 5 V
20 to 100 Hz, ≥ 5 V
100 to 500 Hz, ≥ 10 V
DC Power Range600 kVA (600 V DC range)
1500 kVA (1500 V DC range)
DC Power Resolution0.1 kVA
1 kVA
DC Power Accuracy2 % RD + 2 KVA
2 % RD + 20 kVA
Resistance Range600 Ω
6000 Ω
60 kΩ
Resistance Resolution0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
0.01 k Ω (≤ 60.00 kΩ)
Resistance Accuracy1 % RD + 5 digits
Capacitance Range100.0 μF
1000 μF
Capacitance Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Capacitance Accuracy1 % RD + 5 digits
Capacitance Inrush Trigger Level5 A
Environmental Specifications TemperatureOperating: 14 to 122°F (-10 to 50 °C)
Storage: -40 to 140°F (-40 to 60 °C)
Environmental Specifications Operating HumidityNon-condensing (<10°C)
≤ 90 % RH at 50 to 86°F (10 to 30 °C)
≤ 75 % RH at 86 to 104°F (30 to 40 °C)
≤ 45 % RH at 104 to 122°F (40 to 50 °C)
Environmental Specifications AltitudeOperating: 1.2 miles (2000 m)
Storage: 7.4 miles (12000 m)
General Specifications Maximum Voltage (Between Terminal and Earth Ground)1000 V AC
1500 V DC
General Specifications Batteries2 AA IEC LR6 alkaline
General Specifications DisplayDual display with backlight
General Specifications Automatic power off20 minutes

Reviews

There are no reviews yet.

Be the first to review “True RMS Wireless Clamp Meter with iFlex & CAT III 1500V – Enviro Test Construct”

Your email address will not be published. Required fields are marked *

Scroll to Top