This Water Quality Meter with 12 Multiparameter (Data Storage) is suitable for measuring the pH, mV, Conductivity and TDS of liquids and comes with an extended data storage memory of up to 500 readings.

SKU: ETCYYOOZW Category:

Overview

Enviro Test Construct Water Quality Meter with 12 Multiparameter (Data Storage) is suitable for measuring the pH, mV, Conductivity and TDS of liquids. In the Conductivity/TDS mode the instrument features 1 to 5 points push-button calibration with automatic calibration solution recognition, selectable cell constant (0.1/1/10), normalization temperature, TDS conversion factor and linear or pure water compensation mode. System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc. Stored data can be transferred into computer by USB communication interface.

 

Key Features

  • Equipped with a large backlit LCD display
  • In pH mode, Ito 5 points push-button calibration with auto-buffer recognition and in conductivity/TDS Mode 1 to 5 points push-button calibration with automatic calibration solution recognition
  • Automatic electrode slope display helps user decide whether to replace sensor
  • Selectable cell constant (0.1/1/10), normalization temperature 68 °F/77 °F (20 °c /25°C), TDS conversion factor and linear or pure water compensation mode.
  • Automatic Temperature Compensation provides accurate reading over the entire range
  • Calibration Due Reminder prompts user to calibrate the meter regularly
  • Stability indicator automatically shows current measurement status
  • Auto-Hold function freezes stable measured value for easy viewing and recording
  • Manual temperature calibration corrects temperature deviation
  • Selectable temperature unit (°C or °F) meets different application requirements
  • Automatic electrode diagnosis shows zero point offset and slope of the electrode
  • Help message is an operational guide that helps user quickly begin using the meter
  • System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc
  • Reset feature automatically resumes all parameters back to factory default settings
  • Expanded memory stores and recalls up to 500 readings
  • Built-in real-time clock stamps stored data to meet GLP standard
  • Stored data can be transferred into computer by USB communication interface.

 

Technical Specifications

pH
Range-2.000 pH — 20.000 pH
Accuracy+-0,002 pH
Resolution0.1 pH, 0.01 pH, 0.001 pH (selectable)
Calibration Points1 to 5 points
Calibration SolutionsUSA, NIST, DIN or User-defined Buffer
Temperature Compensation32 °F – 212 °F (0 °C – 100 °C)
Compensation ModeManual or Automatic
mv
Range-1999.9 mV — 1989.9 mV
Accuracy+-0.2 mV
Resolution0.1 mv, 1 mV (Selectable)
Calibration Points1 point (Only for Relative mV mode)
Calibration Range+-200 mV
lon
Range0.001 ppm – 19999 ppm, mg/L, mol/L (depending on the range of ISE)
Accuracy+-0.5 % F.S (monovalent), +1 % F.S (divalent)
Resolution0.001, 0.01, 0.1, 1
Calibration Points2 to 5 points
Calibration Solutions0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 10 ppm, 100 ppm, 1000 ppm, 10000 ppm, mg/L, mol/L
Temperature Compensation32 °F — 212 °F (0 °C – 100 °C)
Compensation ModeManual or Automatic
Conductivity
RangeOus/em — 20.00 ps/cm, 200.0 ps/em, 2000 ps/cm, 20.00, 200.0 ms/cm
Accuracy+-0.5% FS
Calibration Points1to 5 points
Calibration Solutions10 ps/cm, 84 pS/cm, 1413 pS/em, 12.88 mS/cm, 11.8 ms/cm
Temperature Compensation32 °F — 212 °F (0 °C – 100 °C), Manual or Automatic
Temperature Coefficient0.0 %/°C – 10.0 %/°C
Compensation ModesLinear or Pure Water
Cell ConstantK=0.1, 1, 10 or User-defined
TDS
Range0 ppt – 100 ppt (Max. 200 ppt, depending on factor setting)
Accuracy+-1%FS
TDS Factor0.1 – 1.0 (Default 0.5)
Salinity
Range0 ppt — 10 ppt (Max. 80 ppt)
Accuracy+-1%FS
Measurement ModesSeawater or Practical Salinity
Resistivity
Range0 MQ – 100 MQ
Accuracy+-1%FS
Resolution0.01, 0.1, 1
Dissolved Oxygen
Range0.00 mg/L – 20.00 mg/L (or ppm)
Accuracy+-0.2 mg/L
Resolution0.01 mg/L
Calibration Points1 or 2 points
Temperature Compensation32 °F – 122 °F (0 °C – 50 °C), Automatic
Pressure Correction60.0 kPa – 112.5 kPa, 450 mm Hg – 850 mm Hg
Salinity CorrectionOg/L-50 g/t
Saturation of Oxygen
Range0.0 % – 200.0 %
Accuracy+-2.0 %
Resolution0.1%,1%
Temperature
Range32 °F — 221 °F (0 °C – 105 °C)
Accuracy+0.5 °C, 0.9 °F
Resolution32118 F (0.1 °C)
Calibration Points1 point
Calibration RangeMeasured value +(10 °C) 50 F
Others
Hold Function Manual or Automatic
Stability ConditionsLow or High
Calibration Due 0 to 31 days
Power OffManual or Automatic (10 minutes, 20 minutes, 30 minutes)
Reset FunctionYes
MemoryStores up to 500 data sets
OutputUSB Communication Interface
ConnectorBNC, 6-pin Mini Plug
Display LCD
Power RequirementsDC 5 V, using AC adapter, 220 V AC/50 Hz
Dimensions8.2 in x 7.4 in x 2.3 in (210 mm * 188 mm x 60 mm)
Weight3.3 Ibs (1.5 kg)