Enviro Test Construct Laboratory Benchtop Dissolved Oxygen Conductivity Meter

Enviro Test Construct Laboratory Benchtop Dissolved Oxygen Conductivity Meter is High accuracy multiparameter water quality meter contains 13 options, the meter is suitable for measuring the conductivity, TDS, salinity, resistivity and dissolved oxygen.

SKU: ETCLCM-236 Category:

Overview

Enviro Test Construct Laboratory Benchtop Dissolved Oxygen Conductivity Meter is High accuracy multiparameter water quality meter contains 13 options, the meter is suitable for measuring the conductivity, TDS, salinity, resistivity and dissolved oxygen.

 

Features

  • Accurate readings with auto temperature compensation
  • Auto-Read locks measurement endpoint
  • Calibration due alarm for regular maintenance
  • Setup menu for customizable parameters
  • Reset resumes factory default settings
  • Memory stores/recalls up to 500 data sets
  • USB interface for data transfer

 

Technical Specifications

Conductivity
Range0 µS/cm to 20.00 µS/cm, 200.0 µS/cm, 2000 µS/cm, 20.00 mS/cm, 200.0 mS/cm
Resolution0.001, 0.01, 0.1, 1, automatic
Accuracy±0.5% F.S.
Calibration Points1 to 5 points
Calibration Solutions10 µS or 84 µS or 1413 µS or 12.88 mS or 111.8 mS
Temperature Coefficient0.0% to 10.0% / °C
Pure Water CompensationYes
Reference Temperature68 °F or 77 °F (20 °C or 25 °C)
Cell ConstantK=0.1 or 1 or 10 or Custom
TDS
Range0 ppm to 10.00 ppm, 100.0 ppm, 1000 ppm, 10.00, 200.0 ppt
Resolution0.01, 0.1, 1, automatic
Accuracy±1% F.S.
TDS Conversion Factor0.1 to 1.0 (default 0.5)
Salinity
Range0.00 ppt to 80.00 ppt or 0.00 psu to 42.00 psu
Resolution0.01
Accuracy±1% F.S.
Resistivity
Range0 MΩ to 20 MΩ
Resolution0.01
Accuracy±1% F.S.
Dissolved Oxygen
Range0.00 mg/L to 20.00 mg/L or 0.0% to 200.0% saturation
Resolution0.01 or 0.1, selectable
Accuracy±0.2 mg/L or ±2.0 %
Calibration Points1 or 2 points
Pressure Correction0.6 bar to 1.125 bar (60.0 kPa to 112.5 kPa) or 450 mmHg to 850 mmHg, manual
Salinity Correction0.0 g/L to 50.0 g/L, manual
Other Specifications
Hold FunctionManual or Auto-read measurement endpoint
Stability CriteriaLow or High
Calibration Due Alarm1 day to 31 days or off
MemoryStores up to 500 data sets
OutputUSB communication interface
Connector6-pin mini-DIN, 0.13 in (3.5 mm) jack socket
DisplayCustom LCD 4.92 in × 3.93 in (125 mm × 100 mm)
Power Supply5 V DC power adapter
Environmental Conditions32 °F to 122 °F (0 °C to 50 °C), relative humidity < 80%
Temperature
Offset Calibration1 point
Calibration RangeReading 50 °F (±10 °C)
Range32 °F to 221 °F (0 °C to 105 °C)
Resolution32.18 °F (0.1 °C) or 1 °F (-17.22 °C)
Accuracy31.1 °F to 32.9 °F (±0.5 °C) or ±0.9 °F (-0.5 °C to 0.5 °C)
Temperature Compensation32 °F to 212 °F (0 °C to 100 °C), manual or automatic
Dimensions8.26 in × 7.40 in × 2.36 in (210 mm × 188 mm × 60 mm)
Weight3.30 lb. (1.5 kg)