Technical Specifications

EC Range0.00 to 29.99 vs./cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)
EC Resolution0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy±1% Of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration1 Point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)
TDS Resolution0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy±1% Of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS CalibrationThrough EC calibration
EC/TDS Temperature CompensationAutomatic 23 ºF to 212 ºF (-5 ºC to 100 ºC); NoTC – nonabsolute conductivity.
Temperature Correction Coefficient0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor0.40 to 0.80
Salinity (% NaCl) Range0.0 to 400.0% NaCl
Salinity (% NaCl) Resolution0.1% NaCl
Salinity (% NaCl) Accuracy±1% of reading
Salinity (% NaCl) CalibrationSingle point with HI 7037L Standard
Salinity (PSU) Range2.00 to 42.00 PSU
Salinity (PSU) Resolution0.01 PSU
Salinity (PSU) Accuracy±1% Of reading
Salinity Range0.0 to 80.0 g/L
Salinity Resolution (ppt)0.01 g/L
Salinity Accuracy (ppt)±1% Of reading
Temperature Range-4.0 to 248.0 °F (-20.0 to 120.0 ºC)
Temperature Resolution0.18 ºF (0.1 ºC)
Temperature Accuracy±0.9 ºF (±0.5 ºC)
EC/TDS ProbeHI763100 EC/Temperature probe
Logging TypeManual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging MemoryUp to 1000 Records
Connectivity1 Micro-USB port for charging and PC connectivity, 1 USB port for storage
GLPyes
Battery Type/LifeBuilt-in rechargeable battery with up to 8 hours of continuous use
Power Supply5 V DC Adapter (included)
Environment(0 ºC to 50 °C) RH max 95% non-condensing
Dimensions8 in x 5.5 in x 0.5 in (202 mm x 140 mm x 12.7 mm)
Weight8.82 lb. (250 g)