Enviro Test Construct Cable Fault Locator Underground

This Cable Fault Locator Underground has a resolution of reading, 1 m, power dissipation,5 VA, and relative humility, 20 % to 90% RH

SKU: ETCDCGFL-214 Category:

Features

  • Fault Detection Methods
  • Utilizes low-voltage pulse and high-voltage pulse flash-over methods
  • Detects various cable faults, especially flash-over, without cable burning
  • High Precision
  • High-speed data sampling with a 100 MHz A or D sampling rate
  • Read resolution of 1 meter, with a 1m blind spot detection scope
  • Low Static Drift
  • Core components are reliable, imported components
  • High Output Power
  • Internal use of precision high-power tubes for large and non-easily attenuated output signal power
  • Perfect Protection Function
  • Complete internal protection circuit with features like overvoltage and overcurrent protection
  • Portability
  • Built-in rechargeable battery power supply for convenience in various locations
  • High Positioning Accuracy
  • Uses quartz crystal oscillator and high-speed signal processing chip for accurate positioning
  • Features acoustic and magnetic synchronization for reliable positioning accuracy
  • Adaptable Communication Speed
  • Has the ability to adjust communication speed based on the tested cable
  • Anti-Interference Capability
  • Maintains good performance and stability under severe interference conditions
  • High Receiving Sensitivity
  • Special manufacturing technology increases transmission distance
  • Ensures clear signal reception even under challenging conditions

 

Technical Specifications

The Longest Testing Distances15 km (100 km for the open-wire line)
Testing Dead Zone1 m
Resolution Of Reading1 m
Power Dissipation5 VA
Relative Humility20 % to 90% RH
Pathfinders Operation ModeOutput – fixed frequency intermittent square wave signal
Pathfinders Output PowerPomax ≥ 100 W
Pathfinders Output Impedance1 Ω- ∞
Pathfinders Output Signal Frequency16 kHz
Pathfinders Output Signal Amplitude15 V to 340 V
Pathfinders Transmitter Power SupplyAC 220 V ± 10℅
Fault Locator Rough Measurement ErrorLess than 10%
Fault Locator Fixed-Point Error< (± 10 cm)
Fault Locator Electromagnetic Channel Gain>110 dB (300,000 times)
Fault Locator Electromagnetic Channel Receiver Sensitivity<5 μV
Fault Locator Sound Channel Audio Amplifier Gain<120 dB (1 million times when the signal-to-noise ratio is 4:1)
Fault Locator 50Hz Power Frequency Rejection>40 dB (100 times)
Fault Locator Power Consumption<120 mA (0.7 W)
Fault Locator Buried Depth Detection>≦3 m
Environment Temperature32 ℉ to 104 ℉ (0 ℃ or + 40 ℃)
Terminal Temperature(-10 ℃ to +50 ℃)
Dimension10.82 in × 8.61 in × 6.29 in (275 mm × 220 mm × 160 mm3)
Weight3.96 lb (1.8 kg)

Reviews