Enviro Test Construct Benchtop Multiparameter Conductivity Meter

Enviro Test Construct Benchtop Multiparameter Conductivity Meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen etc.

SKU: ETCCMSM-222 Category:

Overview

Enviro Test Construct Benchtop Multiparameter Conductivity Meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen etc.

 

Technical Specifications

Ph Range-2.00 pH to 20.00 pH
Ph Accuracy±0.002 pH
Resolution0.001, 0.01, 0.1 pH, selectable
Calibration PointsUp to 5 points
Calibration SolutionsUSA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75
Ion Concentration Range0.001 to 19999 ppm, mg/L, mol/L (Depending on measuring range of Ion selective Electrode)
Ion Concentration Accuracy±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
Calibration Points2 to 5 points
Calibration Solutions0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Mv Range-1999.9mV to 1999.9mV
Mv Accuracy±0.2mV
Resolution0.1, 1mV, selectable
Conductivity Range0 mS/cm to 20mS/cm (Max.200mS/cm)
Conductivity Accuracy±0.5% Full Scale
Calibration PointsUp to 5 points
Calibration Solutions10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
TDS Range0ppt to 10ppt (Max. 20ppt, depending on factor setting)
TDS Accuracy±1% Full Scale
TDS Factor0.1 to 1.0 (Default 0.5)
Salinity Range0ppt to10ppt (Max.80ppt)
Salinity Accuracy±1% Full Scale
Salinity Measurement ModesPractical Salinity (PSU) or Seawater Measurement Standard (ppt)
Resistivity Range0 to 100MΩ
Resistivity Accuracy±1% Full Scale
Resolution0.001, 0.01, 0.1, 1, Automatic
Temperature Coefficient0.0 to 10.0% per °C
Compensation ModesLinear or Pure Water
Cell ConstantK=0.1, 1, 10, selectable
Normalization Temperature68 °F or 77 °F (20 °C or 25 °C)
Dissolved Oxygen Range0.00 mg/L or ppm to 20.00mg/L or ppm
Resolution0.01, 0.1mg/L, selectable
Dissolved Oxygen Accuracy±0.2mg/L (Calibration and measurement under the conditions of same temperature)
% Saturation of Oxygen0.0% to 200.0%
Accuracy±2.0%
Salinity Correction0 g/L to 50g/L
Pressure Correction8.70 PSI to 16.31 PSI (60.0 kPa to112.5 kPa), 450 mmHg to 850 mmHg
Temperature Range(32 °F to 221 °F) 0 °C to 105 °C
Temperature Accuracy±0.9 °F (±0.5 °C)
Temperature CalibrationManual
Temperature Compensation32 °F to 212 °F (0 °C to 100°C), Automatic or Manual;
DO Mode:32 °F to 122°F (0 °C to 50 °C), Automatic
Auto-OffManual or Automatic (10, 20, 30 minutes after last key pressed, selectable)
Hold FunctionManual or Automatic
Stability ConditionsLow or High, selectable
Calibration Due Reminder0 to 30 days
Reset FunctionYes
Memory500 data sets with Date/Time stamping
OutputUSB Communication Interface
ConnectorBNC and 6-pin connector
Power RequirementsDC 5 V, using AC adapters, 220 V AC/50 Hz
LCD DisplayCustom dual-display LCD 5.118 in x 4.331 in (130 mm x 110 mm)
Dimensions 8.27 in x 7.40 in 2.36 in (210 mm × 188 mm × 60 mm)
Weight 2.64 lb (1.2 kg)

Reviews

There are no reviews yet.

Be the first to review “Enviro Test Construct Benchtop Multiparameter Conductivity Meter”

Your email address will not be published. Required fields are marked *

Scroll to Top