Enviro Test Construct Benchtop Ion Concentration Meter

Enviro Test Construct Benchtop Ion Concentration Meter is a compact, multiparameter photometer for use in the lab or in the field.

SKU: ETCBIM-233 Category:

Overview

Enviro Test Construct Benchtop Ion Concentration Meter is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, This doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements. From aluminium to zinc, this benchtop photometer measures 37 different key water quality parameters using 60 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.

 

Technical Specifications

PH CalibrationAutomatic One Or Two Point Calibration With One Set Of Standard Buffers Available (4.01, 6.86, 7.01, 9.18, 10.01)
PH Temperature CompensationAutomatic 23.0 °F To 212.0 °F (-5.0 °C to 100.0 °C); Limits Reduced Based On The PH Electrode Used
PH CAL Check (Electrode Diagnostics)Clean Electrode And Check Buffer/Check Displayed During Calibration
PH MethodPhotometer
PH-MV Range+1000 MV
PH-MV Resolution0.1 MV
PH-MV Accuracy0.2 MV
Dissolved Oxygen Range0.0 Mg / L To 10.0 Mg / L (As O₂)
Dissolved Oxygen Resolution0.1 Mg / L
Dissolved Oxygen Accuracy+0.4 Mg / L +3% Of Reading
Absorbance Range 0.000 Abs To 4.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy±0.003 Abs @ 1.000 Abs
Alkalinity RangeFreshwater
Alkalinity Resolution1 Mg/L
Alkalinity Accuracy+5 Mg/L ±5% Of Reading
Alkalinity MethodColorimetric Method
Aluminium Range0.00 Mg/L To 1.00 Mg / L (As Al³+)
Aluminium Resolution0.01 Mg/L
Aluminium Accuracy±0.04 Mg/L ±4% Of Reading
Ammonia RangeLow Range
Ammonia Resolution0.01 Mg/L; 0.1 Mg/L
Ammonia AccuracyLow Range
Anionic Surfactants Range0.00 Mg/L To 3.50 Mg/L (As SDBS)
Anionic Surfactants Resolution0.01 Mg/L
Anionic Surfactants Accuracy±0.04 Mg/L ±3% Of Reading
Bromine Range0.00 To 8.00 mg/L (As Bra)
Bromine Resolution0.01 Mg/L
Bromine Accuracy10.08 Mg/L ±3% Of Reading
Calcium RangeFreshwater
Chromium, Hexavalent RangeLow Range
Chromium, Hexavalent Resolution1 µg/L
Chromium, Hexavalent AccuracyLow Range
Color, Water Range0 To 500 PCU (Platinum Cobalt Units)
Color, Water Resolution1 PCU
Color, Water Accuracy±10 PCU ±5% Of Reading
Copper RangeLow Range
Copper Resolution0.001 Mg/L; 0.01 Mg/L
Copper AccuracyLow Range
Cyanuric Acid Range0 Mg/L To 80 Mg/L
Cyanuric Acid Resolution1 Mg/L
Cyanuric Acid Accuracy±1 Mg/L ±15% Of Reading
Fluoride RangeLow Range
Fluoride Resolution0.01 Mg/L; 0.1 Mg/L
Fluoride AccuracyLow Range
Hardness, Total RangeLow Range
Potassium Resolution0.1 Mg/L
Potassium Accuracy±3.0 Mg/L ±7% Of Reading
Silica RangeLow Range
Silica Resolution0.01 Mg/L: 1 Mg/L
Silica Accuray/MethodLow Range
Silver Resolution0.001 Mg/L
Silver Accuracy±0.020 Mg/L ±5% Of Reading
Sulfate Range0 To 150 Mg/L (As 5042)
Sulfate Resolution1 Mg/L
Sulfate Accuracy±5 Mg/L ±3% Of Reading
Zinc Range0.00 To 3.00 Mg/L (As Zn)
Zinc Resolution0.01 Mg/L
Zinc Accuracy±0.03 Mg/L ±3% Of Reading
Input Channels1 PH Electrode Input And 5 Photometer Wavelengths
PH ElectrodeDigital PH Electrode (Not Included)
Photometer/Colorimeter Light Source5 LEDs With 420 Nm, 466 Nm, 525 Nm, 575 Nm, And 610 Nm Narrow Band Interference Filters
Bandpass Filter Bandwidth8 Nm
Bandpass Filter Wavelength Accuracy±1 Nm
Cuvette TypeRound, 0.96 In (24.6 Mm)
Number Of Methods128 Max.
GLPCalibration Data For Connected PH Electrode
Display128 x 64 Pixel LCD With Backlight
Logging TypeLog On Demand With Username And Sample ID Optional Input
Logging Memory1000 Readings
ConnectivityUSB-A Host For Flash Drive: Micro-USB-B For Power And Computer Connectivity
Power Supply5 V DC USB 2.0 Power Adapter With USB-A To Micro-USB-B Cable (Included)
Battery Type/Life3.7 V DC Li-Polymer Rechargeable Battery / >500 Photometric Measurements Or 50 Hours Of Continuous Pt Measurement
Environment32 To 122.0 °F (0 °C To 50.0 °C): 0 To 95% RH, Non-Condensing
Dimensions8.11 In × 6.96 In × 3.81 In (206 Mm x 177 Mm x 97 Mm)
Weight2.2 Lb (1.0 kg)

Reviews

There are no reviews yet.

Be the first to review “Enviro Test Construct Benchtop Ion Concentration Meter”

Your email address will not be published. Required fields are marked *

Scroll to Top