Overview

Enviro Test Construct ammonia gas leak detector has a zero-point automatic tracking; long-term use will not be affected by the zero drift. Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements. Chinese and English interfaces can be selected. Broad operating temperatures: -40 ℃  to +70 ℃, and temperature compensation is supported. Record the calibration logs, repair logs, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration. Meet the requirements on the design of the intrinsically safe circuits, such as anti-static, anti-electromagnetic interference. Protection level is possible to prevent the splash water, dust, and shock.

 

Technical Specifications

Gases To Be DetectedArbitrary combination of 1 to 4 types of gasses such as toxic gasses, oxygen gas, carbon dioxide, inflammable and explosive gasses, TVOC, and so on. Optional configuration: temperature and humidity measurements.
Application ScenariosAll the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection Range0 ppm to 100000 ppm, 200 mg/L, 100 % LEL, 20 %, 50 %, 100 % Vol, can be selected; and other ranges can be customized.
Resolution0.01 ppm or 0.001 ppm (0 ppm to 10 ppm);
0.01 ppm (0 ppm to 100 ppm),
0.1 ppm (0 ppm to 1000 ppm),
1 ppm (0 ppm to  10000 ppm or more),
0.01 mg/l (0 mg/l to  200 mg/l),
0.1 % LEL, 0.01 %, 0.001 % Vol
Detection PrincipleElectrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor Service LifeElectrochemical principle: 2 to 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 to 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 to 3 years.
Allowable Error≤ ± 3 % F.S (higher precision levels can be customized)
Linearity≤ ± 2 %
Uncertainty≤  ± 2 %
Response TimeT 90 ≤ 30 seconds
Recovery Time≤ 30 seconds
Repeatability≤ ± 2 %
Sample Gas Temperature-40 °F to 158 °F (-40 ℃ to + 70 ℃), and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 752 °F (400 ℃) or higher.
Power Supply3.7 V DC, 3000 mA high capacity rechargeable polymer battery
Display Mode2.31-in high-definition color screen
Detection ModeDiffusion type measurement. The calibrated flow rate is 500 ml/minute.
Alarm ModeIt is possible to set a sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication InterfaceUSB (charging and communication), optional: RS485 communication interface
Data StorageStandard configuration is the data storage capacity for 100, 000 entries
Protection LevelIP65
Explosion-proof TypeIntrinsically safe type
Explosion-proof MarkExia II CT4 Ga
Working EnvironmentTemperature: -40 °F to 158 °F (-40 ℃ to + 70 ℃)
Humidity: ≤10 % RH to 95 % RH
Temperature And Humidity MeasurementOptional configuration: temperature at -40 °F to 158 °F (-40 ℃ to + 70 ℃), accuracy level at 32.9 °F (0.5 ℃); humidity at 0 % RH to 100 % RH, precision level at 3 % RH
Dimensions 5.12 in x 2.68 in x 1.34 in (130 mm × 68 mm × 34 mm)
Weight0.44 lb (0.2 kg)

 