Enviro Test Construct DC Ground Fault Locator

Enviro Test Construct DC ground fault locator can be applied to dc systems of any voltage level, equipped with a high-precision detection clamp table, which greatly improves the detection range and anti-interference ability through efficient processing of multiple signals.

SKU: ETCRDGFL-201 Category:

Overview

Enviro Test Construct DC ground fault locator can be applied to dc systems of any voltage level, equipped with a high-precision detection clamp table, which greatly improves the detection range and anti-interference ability through efficient processing of multiple signals. By using an excellent algorithm and advanced fuzzy control calculation theory, the advantages of the insulation branch detected are expressed in numerical form, which fully reflects the advantages of artificial intelligence. In addition, they have accurate judgment of the location of the receiving site. Each test can indicate the location and direction of the receiving site. This instrument is used to find the exact location of the dc system connection of the power plant and substation under the condition of continuous electricity. Various types of ground fault can quickly find out the location, accuracy up to 100%.

 

Features

  • The use is simple: this instrument can be directly used only by switching
  • Safety and reliability: This instrument does not need to stop the floating charger
  • Applicable voltage level: DC systems 220 V, 110 V, 48 V, and 24 V can be used
  • Wide range of applications: any type of power plants, substations, coal mines, etc
  • Easy to carry: the receiver has its battery, no external power supply
  • The DC system continuously searches for the grounding point without affecting
  • It has a strong anti-interference ability and overcomes the influence of distributed
  • Intelligent charging management, reduce charging time and prolong battery

 

Technical Specifications

Output Signal Frequency2.5Hz
Signal No-Load Output Voltage±20 V ±5%
Signal Voltage Amplitude Error<5%
Signal Short Circuit Output Current≤80 mA
Output Port Impact Resistance400 V DC shock
Power Supply VoltageAC 220 V ±10%
Voltage Frequency50 Hz ± 5%
Input Insurance2 A
Maximum Power3 W
Sensitivity Of Signal Current Detection0.5 mA
Signal Generator Impedance40 k Ω
Maximum Output Current2.5 ma
Receiver DisplayNumber 0 to 19
Detect The Maximum Grounding Resistance300 KΩ
Grounding Resistance Measurement Accuracy0 KΩ to 4.5 KΩ Error ≤ 0.5 KΩ
Scope0.01 A to 100 A
Range100 A,50 A,25 A,10 A,5 A,2.5 A,1 A,0.5 A,0.25 A,0.1 A,0.05 A,0.025 A
Overload Capacity150 A
Level 0.05 A (0.1 A to 120 A)
Active Power Measuring Accuracy0.05% or 0.1% (PF ≥ 0.5)
Reactive Power Measuring0.1% or 0.2% (PF ≥ 0.5)
Active Power Measuring Accuracy0.05% or 0.1% (PF ≥ 0.5)
Reactive Power Measuring Accuracy0.1% or 0.2% (PF ≥ 0.5)
Power Supply230 V ± 10% 50 Hz
Maximum Power Consumption300 V A
Relative Humidity≤85%
Working EnvironmentTemperature 68 °F ± 41 °F (20 ℃ ± 5 ℃)

Reviews

There are no reviews yet.

Be the first to review “Enviro Test Construct DC Ground Fault Locator”

Your email address will not be published. Required fields are marked *