Enviro Test Construct Laboratory Probest Water Tester

Optional self-cleaning system to get accurate data for a long time.

SKU: ETCHACM-227 Category:

Overview

Optional self-cleaning system to get accurate data for a long time. Can see and collect data in real-time used with platform software. Calibrate and record 49,000 test data (Can record 6 to 16 probes’ data at a time), can simply connected with the existing network for a simple combination Equipped with all kinds of lengths of extension cables. These cables support internal and external stretch and 20 kg of bearing.

 

Features

  • Easily replace electrode on-site, simplifying maintenance process.
  • The Power Save feature allows flexible sampling interval time settings.
  • Sensor has reverse connection protection for power supply.
  • RS485 A/B terminal protected when connected to power supply.

 

Technical Specifications

Temperature PrincipleThermistor method
Range32 °F to 212 °F (0 °C to 100 °C)
Resolution0.18 °F (0.1 ºC)
Accuracy±0.18 °F (0.1 ºC)
PH Sensor PrincipleGlass electrode method
Range0-14 pH
Resolution0.01 pH
Accuracy±0.1 pH
ORP PrincipleGlass electrode method
ORP Range -1000 mV to +1000 mV
ORP ResolutionORP 0.01 mV
ORP Accuracy ±0.1 mV
Conductivity Sensor PrincipleA pair of platinum gauze electrode
Range1us/cm to 2000 us/cm(K=1)
100 us/cm to 100ms/cm(K=10.0)
Resolution0.1us/cm to 0.01ms/cm (Depending on the range)
Accuracy±3%
Turbidity Sensor PrincipleLight Scattering Method
Range0 to 1000 NTU
Resolution0.1NTU
Accuracy±5%
DO Probe PrincipleFluorescence
Range0 to 20 mg/L; 0 to 20 ppm; 0 to 200%
Resolution0.1%/0.01mg/l
Accuracy±0.1mg/L<8 mg/l
±0.2mg/L>8 mg/l
Chlorophyll Sensor PrincipleFluorescence
Range0 to 500 ug/L
Resolution0.1 ug/L
Accuracy±5%
Blue-Green Algae Sensor PrincipleFluorescence
Range100 to 300,000 cells/mL
Resolution20 cells/mL
Accuracy±5%
Salinity Probe PrincipleConverted by conductivity
Range0 to 1 ppt (K=1.0)
0 ppt to 70 ppt(K=10.0)
Resolution0.001 ppt to 0.01 ppt Depending on range
Accuracy±3%
Ammonia Nitrogen Sensor PrincipleIon selection
Range0.1 mg / L 100 mg/L-N
Resolution0.01 mg/L-N
Accuracy±10% or ±2 mg/L
Nitrate Nitrogen Sensor PrincipleIon selection
Range0.1 to 100 mg/L-N
Resolution0.01 mg/L-N
Accuracy±10% or ±2 mg/L
Chloride Sensor PrincipleIon selection
Range0.5 to 1000 mg/L
Resolution0.01 to 1 mg/L
Accuracy±10% or ±2 mg/L
PrincipleIon selection
Range0.5 to 1000 mg/L
Resolution0.011 mg/L
Accuracy±10% or ±2 mg/L