Overview

High-frequency microwave pulses issued by the guided wave radar propagate along detection components (steel cable or steel rod), met the media to be measured, since the dielectric constant of the mutation, cause reflections, a portion of the pulse energy is reflected back. Transmit pulse and the reflected pulse is proportional to the distance and the time interval measured media.

 

Features

  • As a result of advanced microprocessor and unique Cho Discovery echo processing technology, guided wave radar level meter can be used in a variety of complex conditions.
  • Because of the type of process connections and detection components, making 70X Series Guided Wave Radar Level Meter is suitable for a variety of complex conditions and applications. Such as: high temperature, high pressure and low dielectric constant media.
  • Pulsed work, guided wave radar level instruments transmit power is very low, can be installed in a variety of metals, non-metallic container, no harm to humans and the environment.

 

Technical Parameters

 

ParameterETCSLDL-127-01ETCSLDL-127-02ETCSLDL-127-03ETCSLDL-127-04ETCSLDL-127-05
Suitable MediumLiquid, solid powderLiquid, especially corrosive liquidsSolid powderLiquids, particularly low dielectric constant liquidsLiquids, especially in high temperature and pressure environments
ApplicationLiquid and solid powder measurement in complicated process conditionsAcids, bases, or other corrosive mediaCement silo powder measurement, ash powder measurementMeasuring deionized water, deoxygenated water, and similar liquidsSealed tanks and high-pressure liquid measurement
Explosion-proof GradeExia IIC T6 Ga / Exd ia IIC T6 Gb
Measuring Range30 m20 m30 m6 m15 m
Frequency500 MHz – 1.8 GHz
AntennaSingle cable or single rod antennaFull PTFE sealing cable type or rod antennaDouble cable antennaCoaxial tube type antennaSingle cable or single rod antenna
Accuracy±10 mm±10 mm±10 mm±5 mm±10 mm
Process Temperature-40°C to 250°C-40°C to 200°C-40°C to 150°C-40°C to 250°C-200°C to 400°C
Process Pressure-0.1 to 4 MPa-0.1 to 40 MPa
Signal Output4–20 mA / HART
DisplayFour-line LCD / Programmable
Power SourceTwo-wire (DC 24V) / Four-wire (DC 24V or AC 220V)
ShellAluminum / Plastic
ConnectionFlange (optional) / Thread

 

Technical Specifications

General Parameters

ParameterSpecification
Probe Material – RodStainless Steel 316L / PTFE
Probe Material – CableStainless Steel 316L / PTFE
Probe Material – CoaxStainless Steel 316L / PTFE
SealViton Fluoroelastomer, Kalrez Perfluoroelastomer
Process ConnectionStainless Steel 316L
ShellStainless Steel 316L, Plastic, Aluminum (Alu-die casting, Powder Coated)
Seal Ring (Between Shells)Silicone Rubber
Viewpoint WindowPolycarbonate
Ground TerminalStainless Steel 316L

 

Power Supply

ParameterSpecification
2-Wire Standard Version16–36 V DC
2-Wire Intrinsic Safe Version21.6–26.4 V DC
Power Consumption (2-Wire)Max. 22.5 mA
Ripple Allowed (<100 Hz)Uss < 1 V
Ripple Allowed (100 Hz – 100 kHz)Uss < 10 mV
4-Wire VersionIntrinsic Safe + Explosion-Proof
4-Wire Power Supply22.8–26.4 V DC / 198–242 V AC
Power Consumption (4-Wire)Max. 1 VA / 1 W

 

Cable Parameters

ParameterSpecification
Cable Entry / PlugOne cable entry M20×1.5 (cable diameter 5–9 mm), One blind stopper M20×1.5
Spring Connection TerminalSuitable for cables with cross-section up to 2.5 mm²

Output Parameters

ParameterSpecification
Output Signal4–20 mA / HART
Resolution1.6 μA
Failure Mode20.5 mA / 22 mA / 3.9 mA / Hold
2-Wire Load ResistanceRefer to load diagram
4-Wire Load ResistanceMax. 500 Ω
Integration Time0–40 sec (adjustable)

 