Enviro Test Construct Portable Digital 3 pH Power Quality and Energy Analyzer With 3000A CT Clamp – Voltage flicker

3-Phase Power Analyzer: Digital, Portable, 3000A CT Clamp (10 A to 6000 A). Colour LCD, Data Logging, Alarms, Harmonics (0 to 50).

SKU: ETCPHM-172 Category:

Technical Specifications

Power supplyRechargeable lithium-ion battery pack 9.6 V, backup charger.
Battery indicatorBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute.
Power consumptionCurrent consumption of normal test 490 mA, continuous working for 8 hours.
Number of channels4 U or 4 I
Phase to phase voltage1.0 V to 2000 V
Phase-to-neutral voltage1.0 V to 1000 V
Current10 A current clamp: 10 mA to 10.0 A

100 A current clamp: 0.10 A to 100 A

1000 A current clamp: 1.0 A to 1000 A

6000 A Flexible Coil Current Sensor (with Integrator): 10 A to 6000 A

Frequency40 Hz to 70 Hz
Parameters of electricityW, VA, Var, PF, DPF, cos φ, tan φ
Energy parametersWh, Varh, Vah
HarmonicOrder 0 to 50
Total harmonic distortionOrder 0 to 50, each phase
Expert modeYes
Number of Transient records150 sets
Voltage flickerYes
Starting current modeYes, 100 sec
3 phases unbalanceYes
Record300 days (simultaneous recording 20 parameters, record one point every 5 seconds).
Min or Max recorded valueMeasurement of maximum and minimum values over a period of time
Alarm40 different types of parameter selections, 12,800 sets alarm logs
PeakYes
Phasor diagram displayAutomatically
Capacity of snapshots60
CommunicationUSB
Automatic switching offWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off
Backlight functionYes, suitable for use at night and in a dark place.
Input impedanceInput impedance of test voltage: 1 MΩ
Withstand voltageWithstand 3700 V per 50 Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell
InsulationBetween instrument wiring and shell ≥ 10 M Ω
StructureDouble insulation, with insulation vibration proof sheath
Safely rulesIEC 61010 1000 V Cat III or 600 V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2
Working temperature and humidity14 °F to 104 °F (-10 °C to 40 °C) below 80 % RH
Storage temperature and humidity14 °F to 140 °F (-10 °C to 60 °C)  below 70 % RH
Display modeLCD colour screen, 640 dots × 480 dots, 5.6 inches, display domain: 4.56 in x 3.46 in (116 mm × 88 mm)
Size of clamp10 A small sharp current clamp: 0.29 in x 0.51 in (7.5 mm × 13 mm)

100 A circle current clamp: 1.37 in x 1.57 in (35 mm × 40 mm);

1000 A circle current clamp: 2.67 in x 2.67 in (68 mm × 68 mm.)

6000 A Flexible Coil Current Sensor (with Integrator): 11.8 in (30 cm)

Instrument dimensions9.44 in x 6.69 in x 2.67 in (24 cm×17 cm× 6.8 cm)
Length of voltage test wire78.74 in (300 cm)
Length of current sensor wire118.11 in (200 cm)
WeightHost: 3.53 lb (1.6 kg) (with battery)

10 A small sharp current clamp: 6 oz (170 g) × 4

100 A circle current clamp: 6.7 oz (190 g) × 4

1000 A circle current clamp: 17.99 oz (510 g) × 4

6000 A Flexible Coil Current Sensor (with Integrator): 11.64 oz (330 g) × 4

Test wires and power adapter: 31.75 oz (900 g)

Total Weight 20.28 lb (9.2 kg)
Scroll to Top