Enviro Test Construct Portable Ammonia Gas Detector – Maintenance Free

Enviro Test Construct Portable Ammonia Gas Detector – Maintenance Free, it offers up to 2 years of protection-with no need for calibration, sensor replacement, battery replacement or battery charging.

SKU: ETC AGD-112 Category:

Overview

Enviro Test Construct portable ammonia gas detector – maintenance free is a maintenance-free single gas detector, it offers up to 2 years of protection-with no need for calibration, sensor replacement, battery replacement or battery charging. It’s IECEx, ATEX, CNEX explosion proof certificated and meet the highest standards of quality and reliability to ensure workers’ safety and compliance. It is small, sturdy, ergonomic, and can be attached to a work coat or cap with alligator clips for easy carrying.

 

Features

  • Low power consumption and long standby time, the standby time is up to 2 years
  • Maintenance free: just turn on the device and it will run continuously – no calibration, no sensor replacement, no battery charging
  • Ultra-high buzzer alarm sound, 2 high-bright red LED up and down alarm, sound, light and vibration triple alarm to remind workers
  • High point alarm, low point alarm, TWA, STEL multiple alarm types, the user can adjust the alarm set point as needed throughout the life cycle
  • Automatic logging 10 sets of recent alarm events for easy and accurate record keeping
  • Protection class IP68, splash-proof, dust-proof, explosion-proof, shock-proof, intrinsically safe circuit design
  • Compact and lightweight design with two-button operation without extensive training
  • Affordable, with low cost of ownership
  • Small size, light weight, easy to carry
  • The shell is made of high-strength materials, designed for a variety of harsh environments, comfortable and durable
  • With self-test function, which can improve safety by automatic self-test

Technical Specifications

Detect GasNH3
Sensor TypeElectrochemical
Sampling MethodDiffusion
Measure Range0 ppm to 50 ppm, 0 ppm to 100 ppm
Resolution0.1 ppm
Precision≤ ± 3 % FS
Response TimeT 90 ≤ 30 S
UnitPPM
DisplayGas name, Concentration unit, Measured value and Electricity
Alarm ModeSound, Light, Vibration alarm, High and Low alarm values can be set by yourself
Alarm TypeLow alarm, High alarm, STEL, TWA and Low Battery Alarm
DisplayLCD Display
Working Humidity0 % RH to 95 % RH
Working air pressure12.4 PSI to 15.3 PSI (86 kPa to 106 kPa)
Temperature– 4 °F to 122 °F (- 20 °C to 50 °C)
Dimensions3.54 in × 2.36 in × 1.30 in (9 cm x 6 cm x 3.3 cm)
Weight4.41 oz (125 g)

 