Electrical Safety Analyzer with Harmonics & Voltage Monitoring – Enviro Test Construct

Measure and analyze electrical safety with this advanced analyzer. Monitors harmonics, voltage, current, phase, and power quality for safe electrical systems. 

SKU: ETCBCM-302 Category:

Technical Specifications

Influence FactorTest ItemBase ConditionWorking Condition
Environment TemperatureAll Parameters73,4 °F ± 2 °C (23 °C ± 2) °C14 °F to 104 °F (-10°C to 40°C)
Relative HumidityAll Parameters40% to 60%< 80%
Phase-To-Neutral VoltageAll Parameters(100 ± 1%) V1.0 V to 1000 V
Phase-To-Phase VoltageTrue RMS Phase-To-Phase Voltage(200 ± 1%) V1.0V to 2000 V
CurrentTrue RMS Current(5 ± 1%) A10 mA to 6000 A
Network FrequencyAll Parameters50Hz ± 0.1 Hz40 Hz to 70 Hz
Phase ShiftActive Power And Active EnergyCos φ = 1Cos φ: 0.2 to 1.0
HarmonicAll Parameters< 0.1%0.0% to 100%
Voltage UnbalanceAll Parameters< 10%0.0% to 100%
Working Voltage Of DeviceAll ParametersDC 9.8 V ± 0.1 VDC 9.5 V to 10.5 V
External Electric FieldAll ParametersShould be avoided
Magnetic Field
Measured Lead PositionMeasured Related Parameters Of CurrentTested Wire At The Centre Of Clamp.
Influence FactorTest ItemBase ConditionWorking Condition
Environment TemperatureAll Parameters73,4 °F ± 2 °C (23 °C ± 2) °C14 °F to 104 °F (-10°C to 40°C)
Relative HumidityAll Parameters40% to 60%< 80%
Phase-To-Neutral VoltageAll Parameters(100 ± 1%) V1.0 V to 1000 V
Phase-To-Phase VoltageTrue RMS Phase-To-Phase Voltage(200 ± 1%) V1.0 V to 2000 V
CurrentTrue RMS Current(5 ± 1%) A10 mA to 6000 A
Network FrequencyAll Parameters50Hz±0.1Hz40 Hz to 70 Hz
Phase shiftActive Power And Active EnergyCos φ = 1Cos φ: 0.2 to 1.0
HarmonicAll Parameters< 0.1%0.0% to 100%
Voltage UnbalanceAll Parameters< 10%0.0% to 100%
Working Voltage Of DeviceAll ParametersDC 9.8 V ± 0.1 VDC 9.5 V to 10.5 V
External Electric FieldAll ParametersShould be avoided
Magnetic Field
Measured Lead PositionMeasured Related Parameters Of CurrentTested Wire At The Centre Of Clamp.
Power SupplyRechargeable lithium-ion battery packs 9.6 V, backup charger.
Battery IndicatorBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power ConsumptionCurrent consumption of normal test 490 mA, continuous working for 10 hours.
Display ModeLCD colour screen, 640 dots × 480 dots, 5.6 in, display domain: 4.5 in x 3.4 in (116 mm × 88 mm).
Size Of ClampFR008 small sharp current clamp: 0.31 in x 0.59 in (8 mm × 15 mm);
FR020 circle current clamp: 0.78 in x 0.78 in (20 mm × 20 mm);
FR050 circle current clamp: 1.9 in 1.9 in (50mm × 50 mm).
FR300R Flexible Coil Current Sensor (with Integrator): Ф 11.8 in (300 mm)
Instrument DimensionsL×W×H: 10.7 in x 8.9 in x 4.5 in (277.2 mm × 227.5 mm × 153 mm).
Number Of Channels4U/4I.
Phase-To Phase Voltage1.0 V to 2000 V.
Phase-To-Neutral Voltage1.0 V to 1000 V.
CurrentFR008 current clamp: 10 mA to 10.0 A;
FR020 current clamp: 0.10 A to 100 A;
FR050 current clamp: 1.0 A to 1000 A;
FR300R Flexible Coil Current Sensor (with Integrator): 10 A to 6000 A
Frequency40 Hz to 70 Hz.
Parameters Of ElectricityW, VA, Var, PF, DPF, cos φ, tan φ.
Energy ParametersW h, Var h, Va h.
HarmonicOrder 0 to 50.
Total Harmonic DistortionOrder 0 to 50, each phase.
Expert ModeYes.
Number Of Transient records150 sets.
Voltage FlickerYes.
Starting Current ModeYes, 100 seconds.
3 Phases UnbalanceYes.
Record300 days (simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max Recorded ValueMeasurement of maximum and minimum values over a period of time.
Alarm40 different types of parameter selections, 12.800 sets alarm logs.
PeakYes.
Phasor Diagram DisplayAutomatically.
Capacity Of Snapshots60.
Menu LanguageEnglish or Chinese.
CommunicationUSB.
Automatic Switching OffWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight FunctionYes, suitable for use at night and dark place.
WeightHost: 3.5 lb (1.6kg) (with battery).
FR008 small sharp current clamp: 0.35 lb x 4 (0.168 kg × 4);
FR020 circle current clamp: 0.55 lb x 4 (0.252 kg × 4);
FR050 circle current clamp: 0.94 lb x 4 (0.463 kg × 4);
FR300R Flexible Coil Current Sensor (with Integrator): 0.61 lb x 4 (0.28 kg × 4);
Test wires and power adapter: 1.7 lb (0.8 kg);
Total weight: about 23.8 lb (10.8 kg) (with packaging).
Length Of Voltage Test Wire3 m.
Length Of Current Sensor Wire2 m.
Input ImpedanceInput impedance of test voltage: 1 M Ω.
Withstand VoltageWithstand 3700 V/50 Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
InsulationBetween instrument wiring and shell ≥ 10 M Ω.
StructureDouble insulation, with insulation vibration-proof sheath.
Safely RulesIEC 61010 1000V Cat III or 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Working Temperature And Humidity14 °F to 104 °F (-10 °C to 40 °C); below 80% Rh.
Storage Temperature And Humidity14 °F to 140 °F (-10 °C to 60 °C); below 70% Rh.