Electrical Safety Analyzer with Harmonics & Voltage Monitoring – Enviro Test Construct

Measure and analyze electrical safety with this advanced analyzer. Monitors harmonics, voltage, current, phase, and power quality for safe electrical systems. 

SKU: ETCBCM-302 Category:

Technical Specifications

Influence Factor Test Item Base Condition Working Condition
Environment Temperature All Parameters 73,4 °F ± 2 °C (23 °C ± 2) °C 14 °F to 104 °F (-10°C to 40°C)
Relative Humidity All Parameters 40% to 60% < 80%
Phase-To-Neutral Voltage All Parameters (100 ± 1%) V 1.0 V to 1000 V
Phase-To-Phase Voltage True RMS Phase-To-Phase Voltage (200 ± 1%) V 1.0V to 2000 V
Current True RMS Current (5 ± 1%) A 10 mA to 6000 A
Network Frequency All Parameters 50Hz ± 0.1 Hz 40 Hz to 70 Hz
Phase Shift Active Power And Active Energy Cos φ = 1 Cos φ: 0.2 to 1.0
Harmonic All Parameters < 0.1% 0.0% to 100%
Voltage Unbalance All Parameters < 10% 0.0% to 100%
Working Voltage Of Device All Parameters DC 9.8 V ± 0.1 V DC 9.5 V to 10.5 V
External Electric Field All Parameters Should be avoided
Magnetic Field
Measured Lead Position Measured Related Parameters Of Current Tested Wire At The Centre Of Clamp.
Influence Factor Test Item Base Condition Working Condition
Environment Temperature All Parameters 73,4 °F ± 2 °C (23 °C ± 2) °C 14 °F to 104 °F (-10°C to 40°C)
Relative Humidity All Parameters 40% to 60% < 80%
Phase-To-Neutral Voltage All Parameters (100 ± 1%) V 1.0 V to 1000 V
Phase-To-Phase Voltage True RMS Phase-To-Phase Voltage (200 ± 1%) V 1.0 V to 2000 V
Current True RMS Current (5 ± 1%) A 10 mA to 6000 A
Network Frequency All Parameters 50Hz±0.1Hz 40 Hz to 70 Hz
Phase shift Active Power And Active Energy Cos φ = 1 Cos φ: 0.2 to 1.0
Harmonic All Parameters < 0.1% 0.0% to 100%
Voltage Unbalance All Parameters < 10% 0.0% to 100%
Working Voltage Of Device All Parameters DC 9.8 V ± 0.1 V DC 9.5 V to 10.5 V
External Electric Field All Parameters Should be avoided
Magnetic Field
Measured Lead Position Measured Related Parameters Of Current Tested Wire At The Centre Of Clamp.
Power Supply Rechargeable lithium-ion battery packs 9.6 V, backup charger.
Battery Indicator Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power Consumption Current consumption of normal test 490 mA, continuous working for 10 hours.
Display Mode LCD colour screen, 640 dots × 480 dots, 5.6 in, display domain: 4.5 in x 3.4 in (116 mm × 88 mm).
Size Of Clamp FR008 small sharp current clamp: 0.31 in x 0.59 in (8 mm × 15 mm);
FR020 circle current clamp: 0.78 in x 0.78 in (20 mm × 20 mm);
FR050 circle current clamp: 1.9 in 1.9 in (50mm × 50 mm).
FR300R Flexible Coil Current Sensor (with Integrator): Ф 11.8 in (300 mm)
Instrument Dimensions L×W×H: 10.7 in x 8.9 in x 4.5 in (277.2 mm × 227.5 mm × 153 mm).
Number Of Channels 4U/4I.
Phase-To Phase Voltage 1.0 V to 2000 V.
Phase-To-Neutral Voltage 1.0 V to 1000 V.
Current FR008 current clamp: 10 mA to 10.0 A;
FR020 current clamp: 0.10 A to 100 A;
FR050 current clamp: 1.0 A to 1000 A;
FR300R Flexible Coil Current Sensor (with Integrator): 10 A to 6000 A
Frequency 40 Hz to 70 Hz.
Parameters Of Electricity W, VA, Var, PF, DPF, cos φ, tan φ.
Energy Parameters W h, Var h, Va h.
Harmonic Order 0 to 50.
Total Harmonic Distortion Order 0 to 50, each phase.
Expert Mode Yes.
Number Of Transient records 150 sets.
Voltage Flicker Yes.
Starting Current Mode Yes, 100 seconds.
3 Phases Unbalance Yes.
Record 300 days (simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max Recorded Value Measurement of maximum and minimum values over a period of time.
Alarm 40 different types of parameter selections, 12.800 sets alarm logs.
Peak Yes.
Phasor Diagram Display Automatically.
Capacity Of Snapshots 60.
Menu Language English or Chinese.
Communication USB.
Automatic Switching Off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight Function Yes, suitable for use at night and dark place.
Weight Host: 3.5 lb (1.6kg) (with battery).
FR008 small sharp current clamp: 0.35 lb x 4 (0.168 kg × 4);
FR020 circle current clamp: 0.55 lb x 4 (0.252 kg × 4);
FR050 circle current clamp: 0.94 lb x 4 (0.463 kg × 4);
FR300R Flexible Coil Current Sensor (with Integrator): 0.61 lb x 4 (0.28 kg × 4);
Test wires and power adapter: 1.7 lb (0.8 kg);
Total weight: about 23.8 lb (10.8 kg) (with packaging).
Length Of Voltage Test Wire 3 m.
Length Of Current Sensor Wire 2 m.
Input Impedance Input impedance of test voltage: 1 M Ω.
Withstand Voltage Withstand 3700 V/50 Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
Insulation Between instrument wiring and shell ≥ 10 M Ω.
Structure Double insulation, with insulation vibration-proof sheath.
Safely Rules IEC 61010 1000V Cat III or 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Working Temperature And Humidity 14 °F to 104 °F (-10 °C to 40 °C); below 80% Rh.
Storage Temperature And Humidity 14 °F to 140 °F (-10 °C to 60 °C); below 70% Rh.

Reviews

There are no reviews yet.

Be the first to review “Electrical Safety Analyzer with Harmonics & Voltage Monitoring – Enviro Test Construct”

Your email address will not be published. Required fields are marked *

Scroll to Top