Enviro Test Construct Multi Parameter ORP Meter

This Multi Parameter ORP Meter Has Measuring Range of -2.000 pH to 20.000 pH, Measuring Range of 2000.0 mV, and ± 0.002 pH of Measurement Accuracy.

SKU: ETCPMWOU-203 Category:

Overview

This Multi Parameter ORP Meter Has Measuring Range of -2.000 pH to 20.000 pH, Measuring Range of 2000.0 mV, and ± 0.002 pH of Measurement Accuracy.

 

Features

  • Automatic temperature compensation ensures high precision measurement over the full-scale range
  • Automatic endpoint lock retains stable readings for easy viewing and recording
  • Interval reading mode periodically sends measured values to a PC or printer
  • Password protection prevents unauthorized calibration and setup
  • Extended memory can store up to 1000 sets of data
  • USB communication interface is easy to connect external devices
  • One key reset automatically restores the meter to the factory default settings

 

Technical Specifications

Measuring Range-2.000 pH to 20.000 pH
 Measurement Accuracy± 0.002 pH
 Display Resolution0.01 pH, 0.001 pH, optional
 Calibration Points1 to 5 points
 pH Buffer OptionsUSA, NIST, DIN, custom
 Measuring Range± 2000 mV
 Measurement Accuracy± 0.2 mV
 Calibration Point1 point (only for relative mV mode)
 Measuring Range0.001 ppm to 30000 ppm, mg per L, mol per L, mmol per L (depending on the range of the ion selective electrode)
 Measurement Accuracy± 0.5 % F.S. (one ion), ± 1 % F.S. (two ion)
 Calibration Points2 to 5 points
 Use Standard Solution0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mg per L, mol per L, mmol per L
 Measuring Range0.05 mmol per L to 200 mmol per L, 0 °dH  to 1120 °dH, 0 °e to 1404 °e, 0 °fH  to 2000 °fH, 0 mg per L to 8000 mg per L (Ca2+), 0 mg per L to 19999 mg per L (CaCO3), 0 mg per L to 11220mg per L (CaO)
 Measurement Accuracy± 1 % F.S.
 Calibration Points2 to 5 points
 Use Standard Solution0.01 mmol per L, 0.1 mmol per L, 1 mmol per L, 10 mmol per L, 100mmol per L
 Calibration Point1 point
 Data LockManual or Automatic Endpoint Lock
 Data Stability ConditionsStandard or high precision
 Calibration Reminder1 to 31 days or off
 Interval Readings10, 30, 60 seconds, 10, 30 minutes or off
 Data Storage1000 groups
 Communication OutputUSB
 ConnectorBNC
 Power TypeDC 12 V power adapter
 Measuring Range32 °F to 221 °F (0 °C to 105 °C)
 Measurement Accuracy± 0.9 °F (± 0.5 °C)
 Temperature Compensation Range32 °F to 212 °F (0 °C to 100 °C), manual or automatic
Dimensions9.44 in x 7.87 in x 3.15 in (240 mm × 200 mm × 80 mm)
Meter Weight3.75 lb (1.7 kg)