Enviro Test Construct Multi-Parameter Benchtop pH, EC, TDS Meter

Multi-parameter Benchtop pH, EC, TDS Meter is a lab grade meter. Data storage, USB export, auto sensor ID. Rugged, waterproof design.

SKU: ETCPHM-191 Category:

Features

  • The host with IP 67 protection rating
  • 5 in (127 mm) color screen display, interface menu design is beautiful
  • Ergonomic curve design
  • With data storage function, data export through USB interface
  • Built-in rechargeable battery and charging directly via USB
  • Automatically identify the connected sensor type
  • The sensor can be parameterized and calibrated

 

Technical Specification

pH PrincipleGlass electrode method
pH Measure Range0 pH to 14 pH
pH Resolution0.01 pH
pH Accuracy± 0.1 pH
ORP PrincipleGlass electrode method
ORP Measure Range-2000 mV to 2000 mV
ORP Resolution1 mV
ORP Accuracy± 2 mV (Electronic component)
Conductivity PrincipleConductivity cell method
Conductivity Measure Range0 us per cm to 20000 us per cm (K=1)
Conductivity Resolution0.1 uS per cm to 0.01 mS per cm (base on range)
Conductivity Accuracy± 1.5 % or ± 2 us per cm, bigger one
Dissolved oxygen PrincipleFluorescence method
Dissolved oxygen Measure Range0 mg per L to 20 mg per L;
0 ppm to 20 ppm;
0 % to 200 %
Dissolved oxygen Resolution0.1% or 0.01 mg per l
Dissolved oxygen Accuracy± 0.3 mg per l
Turbidity PrincipleLight scattering
Turbidity Measure Range0.1 NTU to 1000 NTU
Turbidity Resolution0.01 NTU to 0.1 NTU, based on range
Turbidity Accuracy± 5 % or 0.3 NTU bigger one
Turbidity (Total suspended

Solids)

Principle

Light scattering
Turbidity (Total suspended

Solids)

Measure Range

0.01 mg per L to 20000 mg per L0.01 mg per L to 45000 mg per L;
0.01 mg per L to 120000 mg per L
Turbidity (Total suspended

Solids)

Resolution

0.01 mg per L to 1 mg per L,
based on range
Chlorophyll PrincipleFluorescence method
Chlorophyll Measure Range0 ug per L to 500 ug per L
Chlorophyll Resolution0.01 ug per L
Chlorophyll Accuracy± 5 % of the signal level of 1 ppb
Chlorophyll LinearityR 2 > 0.999
Blue-green algae PrincipleFluorescence method
Blue-green algae Measure Range0 cells per mL to 300,
000 cells per mL
Blue-green algae Resolution20 cells per mL
Blue-green algae Accuracy± 10 % of the signal level of 1 ppb
Blue-green algae LinearityR 2 > 0.999
TypePortable
DisplayLCD Display
Power supply12 V
Protection gradeIP68
Power Dissipation3 W
Temp. PrincipleThermal method
Temp. Measure Range32 °F to 140 °F (0 ℃ to 60 ℃)
Temp. Resolution32 °F (0.01 ℃)
Temp. Accuracy32.9 °F (± 0.5 ℃)
Measuring Temp32 °F to 122 °F (0 ℃ to 50 ℃) (non-freezing)
Size (mm)3.5 in x 23.6 in (9 cm x 60 cm)
Weight6.61 lb (3 Kg)