PH Meter with ORP and Conductivity Range (Data Storage, Accurate)

SKU: ETC00Y400ZD Category:

 

Key Features

  • Optional 5 kinds of PH buffer solution can make 1-3 points automatic calibration
  • Can test PH value for ultrapure water, pure water and boiler water by adjusting equipotential point and special electrode
  • Ability to store test result, cancel, view and print. Can store 1000 sets of data
  • With waterproof portable suitcase and folding holder, the level of protection for outer layer is IP67
  • Automatic identification of 12 kinds of PH standard buffer solution. There are USA, NIST and CH series of standard buffer solution for option. Custom solution calibration
  • Automatic identification of 8 kinds of conductivity standard solution. There are USA and CH series of standard solution for option. Custom solution calibration
  • With intelligent functions of time display, full automatic calibration, automatic power off, power-off protection, automatic calibration, automatic or manual temperature compensation, automatic diagnosis
  • Under voltage prompt and automatic power off can extend battery life

Technical Specifications

CategoryProduct NameBasic features and specifications
PHMeasuring range(-2.00 ~ 19.99)pH  /(-2.00 ~ 19.99)pH
Resolution0.1/0.01 pH  /0.1/0.01 pH
AccuracyMeter:±0.01pH; Overall: ±0.02pH  /Meter:±0.01pH; Overall: ±0.02pH
Input impendance≥1×1012 Ω  /≥1×1012 Ω
Stability±0.01 pH/3h  /±0.01 pH/3h
Temp. compensation range(0 ~ 100)℃(automatic)  /(0 ~ 100)℃(automatic)
ORPMeasuring range (mV/ORP/EH)-1999mV ~ 0 ~ 1999mV-1999mV ~ 0 ~ 1999mV
Resolution1mV1mV
Accuracy:±0.1% FS:±0.1% FS
ConductivityMeasuring rangeConductivity:(0.00~19.99)μS/cm (20.0~199.9)μS/cm (200~1999)μS/cm (2.00~19.99)mS/cm (20.0~199.9)mS/cm TDS: (0 ~ 100)g/L Salinity: (0 ~ 100)ppt Resistivity:(0 ~ 100)MΩ·cmConductivity:(0.00~19.99)μS/cm (20.0~199.9)μS/cm (200~1999)μS/cm (2.00~19.99)mS/cm (20.0~199.9)mS/cm TDS: (0 ~ 100)g/L Salinity: (0 ~ 100)ppt Resistivity:(0 ~ 100)MΩ·cm /
Resolution0.01/0.1/1μS/cm 0.01/0.1 mS/cm0.01/0.1/1μS/cm 0.01/0.1 mS/cm  /
Accuracy±1.0% FS, Overall:±1.5% FS0.01/0.1/1μS/cm 0.01/0.1 mS/cm  /
Temp. compensation range32 to 122°F(0 ~ 50℃ manual)(0 ~ 50)℃(manual)

32 to 122 °F

  /
Electrode constant0.1 / 1 / 10 cm-10.1 / 1 / 10 cm-1  /
Other Technical ParametersData storage1000 groups
PowerTwo AA batteries (1.5V x2)
Size and weight 14.17 x 10.63 x 2.99 in(360×270×76 mm)/3.53 lbs.(1.6Kg)
Working ConditionEnvironment temperature41 to 95 °F (5  to 35 ℃)(0.01grade)
Environmental humidity≤85% / /
IP ratingIP57 Dustproof and waterproof /