Enviro Test Construct Current Voltage Resistance Process Calibrator

Enviro Test Construct current voltage resistance process calibrator is well designed and is suitable for process industries that focus on wide workloads and calibration capabilities.

SKU: ETCDVTPC-102 Category:

Overview

Enviro Test Construct current voltage resistance process calibrator is well designed and is suitable for process industries that focus on wide workloads and calibration capabilities. It can measure and simulate almost all process parameters with high precision, and accurately calibrate almost all process parameters. It is also suitable for higher metrology requirement

 

Features

  • Accurately measure and stimulate output performance with an accuracy of 0.01%
  • Wide measurement range and output capacity
  • Two independent channels, allows simultaneously measure
  • Output and view process signals
  • Measure signals such as voltage or mA or RTD or thermocouple
  • Measure signals such as Frequency or pulse and resistance
  • Output and simulate these signals for transmitter calibration
  • Use synchronized pressure measurements
  • Output mA signals to perform valve and l or P testing
  • Use auto step and auto ramp function to quick perform linearity tests
  • Use 24 V loop power to power the transmitter while measuring mA
  • HART communication function, 232 and Bluetooth

 

Technical Specifications

VoltageRange 0 mV to 100 mV
Resolution 0.01 mV
Accuracy 0.01%+10 uV
Range 0 V to 20 V, 0 V to 30 V
Resolution 1 mV
Accuracy 0.01% + 2 uA
CurrentRange 0 mA to 24 mA
Resolution 1 uA
Accuracy 0.01% + 2 uA
Voltage (TC)Range -10 mV to 75 mV
Resolution 0.01 mV
Accuracy 0.01%+10 uV
ResistanceRange 5 Ω to 400 Ω
Resolution 0.01
Accuracy 0.01%+0.05 Ω
Range 400 Ω to 4000 Ω
Resolution 0.1
Accuracy 0.01%+0.5 Ω
FrequencyRange 2 CPM to 1000 CPM
Resolution 0.1
Accuracy 0.05%+0.1CPM
Range 1 Hz to 1000 Hz
Resolution 0.1
Accuracy 0.05%+0.1 Hz
Range 1 kHz to 15 kHz
Resolution 0.01
Accuracy 0.05%+0.1 kHz
Thermal ResistanceRange NI100(618) or NI100(672) or PT100(385) or PT100(3916) or PT100(3926) or PT200(385) or PT500(385) or PT1000(385) or Cu10(427) or Cu50(428) or Cu100(428)
Resolution 0.01
Accuracy 32.27 °F (0.15 °C)
Pulse Output0 to 10000
Pulse Measurement0 to 100000
Use time30 hrs
Power5 AA alkaline batteries
Size8.19 in x 3.74 in x 1.77 in (208 mm x 95 mm x 45 mm)
Weight1.34 lb (610 g)