Enviro Test Construct Medical Use Ion Meter

This Medical Use Ion Meter has a pH range of -2.000 pH to 20.000 pH, ORP range of ±2000.0 mV, and ion resolution of 0.001, 0.01, 0.1, 1.

SKU: ETCMIMM-209 Category:

Features

  • Accurate auto temperature compensation
  • Auto-Read locks measurement endpoint
  • Timed readings for PC/printer
  • Limit Alarm for exceeding range
  • Calibration due reminder
  • Password protection for security
  • Memory for 1000 data sets
  • Reset restores factory defaults

 

Technical Specifications

PH Range-2.000 pH to 20.000 pH
PH Resolution0.001, 0.01, selectable
PH Accuracy±0.002 pH
PH Calibration Points1 point to 5 points
PH Buffer OptionsUSA, NIST, DIN, 5 custom buffers
ORP Range±2000.0 mV
ORP Relative mV Range±2000.0 mV
ORP Resolution0.1 mV
ORP Accuracy±0.2 mV
ORP Calibration Points1 point
Ion Range0.001 to 30000 (depending on the range of ISE)
Ion Resolution0.001, 0.01, 0.1,1
Ion Accuracy±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Ion Measurement Unitsppm, mg/L, mol/L, mmol/L
Ion Calibration Points2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Ion Measurement MethodsDirect reading, known addition, known subtraction, sample addition, sample subtraction
Ion Electrode Management1 electrode to 3 electrodes
Water Hardness Range 0.05 mmol / L to 200 mmol / L, 0 °dH to 1122 °dH, 0 °e to 1404 °e, 0 °FH to 2000 °FH, 0 mg / L to 8000 mg / L (Ca2)
Water Hardness Resolution0.001, 0.01, 0.1, 1
Water Hardness Accuracy±1% F.S.
Water Hardness Calibration Points2 points to 5 points (0.01, 0.1, 1, 10, 100 mmol / L)
Stability CriteriaStandard or high accuracy
Calibration Due Alarm1 days to 31 days or off
Interval Readings10 sec, 30 sec, 60 sec, 10 min, 30 min or off
Password Protection4 digits
Memory1000 data sets
Communication InterfaceUSB
ConnectorBNC, 0.13 in (3.5 mm) jack socket
Display7 in TFT LCD
Power RequirementsDC 12 V power adapter
Temperature Range32 °F to 221 °F (0 °C to 105 °C)
Temperature Resolution32.18 °F (0.1 °C) or 0.93 °F (−17.61 °C)
Temperature Accuracy±31.1 °F to ±33.9 °F (±0.5 °C) or + 0.9 °F (−17.28 °C)
Temperature Offset Calibration1 point, reading ±14 °F to ±50 °F (±10 °C)
Temperature Compensation32 °F to 212 °F (0 °C to 100 °C), manual or automatic
Solution Temperature Coefficient77 °F (25 °C)
Dimensions9.44 in × 8.66 in × 3.14 in (240 mm x 220 mm × 80 mm)
Weight3.74 lb. (1.7 kg)

 

Reviews

There are no reviews yet.

Be the first to review “Enviro Test Construct Medical Use Ion Meter”

Your email address will not be published. Required fields are marked *

Scroll to Top