This Ammonia Gas Test Equipment has a measure range of 0 ppm to 100 ppm, 200 ppm, 500 ppm, 1000 ppm, precision of 2 %, and response time of ≤ 10 S.

SKU: ETCHAGD-204 Category:

Features

  • Using imported high precision Infrared principles sensor
  • LCD displays gas type, unit, concentration, max values, time, and temperature precisely
  • Gas concentration unit PPM, mg or m3 can quickly switch display
  • Built-in micro sampling pump, the pump suction size ten stalls adjustable
  • Explosion proof certification, proof grade: Exia II CT4

 

Technical Specifications

Gas DetectedNH3 Ammonia
Detection PrincipleElectrochemical principles
Measure Range0 PPM to 100 PPM, 200 PPM, 500 PPM, 1000 PPM
Resolution0.01 ppm, 1 ppm
Sampling MethodPump suction, flow up 1L or min, pump suction size ten stalls adjustable
Precision2 %
Data Logger100,000 sets of data can be stored, storage space available set, minimum 5 S, can be browse
Response Time≤ 10 S
Repeatability≤ ±1 %
Zero Shift≤ ±1 % (F.S or Year)
Operating LanguageSupport in English
Explosion ProofExia Ⅱ CT4
Alarm ModeSound, light, vibration
Recovery Time≤ 10 S
Linearity Error≤ ±1 %
DisplayLCD dot matrix display technology
Gas UnitSupport for multiple gas unit switch display
Humidity0 % RH to 95 % RH
Degree Of ProtectionIP66
Standard1 host computer, 1 charging plug, 1 aluminium alloy packing box, 1 manual,
OptionalData download (EXCEL format) function, detachable needle, hose, holster, waterproof and dust proof filter, high temperature probe (up to 2192 degrees)
Temperature-40 °F to 158 °F (-40 °C to 70 °C)
Dimensions8.07 in × 2.95 in × 1.26 in (205 mm x 75 mm x 32mm)
Weight (Net Or Gross)0.73 lb (0.33 kg)