Overview
Enviro Test Construct provides a reliable battery testing system built to deliver accurate evaluation of battery packs and cells. It performs multiple functions such as open circuit voltage measurement, AC internal resistance, charge and discharge analysis, and overcurrent protection. With programmable test control, users can easily set customized parameters for different applications. Data is stored automatically and can be exported to Excel for detailed study and reporting. The system ensures fast, precise, and consistent performance, making it ideal for industries like electric vehicles, renewable energy storage, aerospace, and telecom. Equipped with barcode management, powerful cooling, and high load capacity, it supports both R&D and production needs.
Features
- Fast testing speed
- High measurement accuracy
- Programmable test control
- Automatic data saving
- Barcode data tracking
- Serial communication support
Technical Specifications
| Open Circuit Voltage | |
| Test Range | 10V to 100 V |
| Resolution | 2 mV |
| AC Internal Impedance | |
| Test Range | 0 mΩ to 1000 mΩ |
| Resolution | 1 mΩ |
| Discharge Test | |
| Starting Voltage Range | 0 V to 100 V |
| Starting Voltage Resolution | 2 mV |
| End Voltage Range | 0 V to 100 V |
| End Voltage Resolution | 2 mV |
| Discharge Current Range | 0.1 A to 150 A |
| Discharge Current Resolution | 1 mA |
| Discharge Time Range | 0 S to 60 S |
| Discharge Time Resolution | 1 mS |
| Discharge Over Current Test | |
| Over Discharge Current Range | 10 A to 300 A |
| Over Discharge Current Resolution | 1 mA |
| Over Current Delay Range | 0 S to 30 S |
| Over Current Delay Resolution | 1 mS |
| Charging Test | |
| Starting Voltage Range | 10 V to 100 V |
| Starting Voltage Resolution | 2 mV |
| End Voltage Range | 10 V to 100 V |
| End Voltage Resolution | 2 mV |
| Charge Current Range | 0.1 A to 20 A |
| Charge Current Resolution | 1 mA |
| Charge Time Range | 0 S to 60 S |
| Charge Time Resolution | 1 mS |
| Charging Protection Test | |
| Charging Overcurrent Range | 4 A to 20 A |
| Charging Overcurrent Resolution | 1 mA |
| Charging Delay Range | 0-20 S |
| Charging Delay Resolution | 0.1 mS |
| Resistance R1/R2 (NTC, ID) | |
| Test Range | 0 KΩ to 1000 KΩ |
| Resolution | 0.1 KΩ |
| Power Specifications | |
| Sustainable Output Power | 2 KW |
| Sustainable Load Power | 15 KW |
| Connectivity | |
| Online Mode | Serial communication (RS232), multi-computer online |
| Data Management | |
| Test Data | Automatically saved, exportable to Excel |
| Barcode Management | Supports barcode startup and binding test data |
| Physical Specifications | |
| Heat Dissipation | Ventilation system and forced air cooling |
| Dimensions (WDH) | 49.2 in x 30.3 in x 40.9 in (125 cm x 77 cm x 104 cm) |
| Weight | 441 lbs (200 KG) |